How does regenerative condenser work


Purpose of regenerative condenser

- to increase thermal efficiency by using some of the steam in the shell of the condenser to reheat the falling condensate to be used for boiler feed water

How does regenerative condenser work:

- baffle plates in a shell and tube condenser are arranged in a configuration which allows most of the steam that enters the shell of the condenser to come in contact with the cooling tubes containing the cooling medium

- majority of the steam then condenses and fall to the condenser hot well

- a portion of the steam, however, is distributed by means of the design of the baffle plates so that it will direct this portion of steam to bypass the cooling tubes and flow directly to the bottom of the shell in order to reheat the falling condensate (the condensate which was the "most of the steam", that is now condensed by means of the cooling medium in the tubes)

- this process will make the temperature of the condensate from the hot well to approach the saturation temperature at condenser pressure

- when the condensate is near the saturation point, the unwanted corrosive non-condensable gases such as oxygen and carbon dioxide will escape

 

Sunday, December 1, 2013

Purpose of Staging in Turbines


Why turbines have stages?

What is a steam turbine stage?

- a stage is a pair of rotating and stationary blades (diaphragm, nozzle)
- the rotating blades are attached to the rotor
- the stationary blades (stators) are attached to the turbine casing
- steam pressure and temperature drops as it expands and passes to the stages
- steam expansion means increase in volume meaning larger surface area


Why do steam turbines have multiple stages? Why not just use a single stage turbine?

- one stage extracts only a small portion of the available energy from the steam
- more stages means more energy extracted
- more energy means more mechanical work at the shaft
- more work means more power (shaft horsepower)



Why turbines need higher vacuum (lower pressure)?

- higher condenser vacuum pressure (lower pressure) means lower exhaust temperature of the steam
- higher vacuum pressure means higher thermal efficiency
- higher efficiency means higher power output
- higher efficiency means lesser power losses


Pressure is inversely proportional to Area


HIGH PRESSURE (HP) TURBINE
- steam is at Higher pressure
- steam is at Higher temperature
- steam is at Higher speed
- turbine has Lesser area (lesser diameter)

LOW PRESSURE (LP) TURBINE

- steam is at Lower pressure
- steam is at Lower temperature
- steam is at Lower speed
- turbine has Larger area (larger diameter)

Monday, September 23, 2013

Pumps in Parallel, Pumps in Series Connection

Two Pumps Connected in Parallel


- purpose: to pump fluid in higher capacities, higher volume, higher amount

- head is constant (total dynamic head is the same, uniform)

- higher discharge volumes

- increase in total pumping capacity

- add flowrates of pumps


Total Flow = Flowrate of Pump1 + Flowrate of Pump2

Q = q1 + q2


Two Pumps Connected in Series


- purpose: to pump fluid in higher elevation, higher height, higher level

- fluid flowrate is constant (the same, uniform)

- higher discharge heights

- increase in total dynamic head

- add heads of pumps 


Total Dynamic Head = Head of Pump1 + Head of Pump2

TDH = H1 + H2

Wednesday, July 17, 2013

Air Conditioning Heat Load Calculation (Room & Building estimate)


The calculation estimate formulas used here are just rough approximations to simplify the total heat load calculations and quickly select an air conditioning unit capable of providing the necessary cooling of the room or space.


--------------------- QUICK HEAT LOAD CALCULATION ESTIMATE -------------------

Typical Room or Small Office:


Space Heat Load = Cooling Space Dimensions x 4

Space Heat Load = Room Length (ft) x Room Width (ft) x Room Height (ft) x 4

Space Heat Load = L x W x H x 4


Occupant Load = 600 BTU/person


Total Heat Load = Space Heat Load + Occupant Load




------------------- DETAILED HEAT LOAD CALCULATION ESTIMATE ------------------
     
1 Btu (British thermal unit)
1 Btu = energy required to cool or heat 1 pound of water by 1 degree Fahrenheit

Heat Load of People
Heat generated per person = 600 Btu

Units:

1 Btu = 0.3 watt hours
1 Btu = 250 calories
1 Btu = 0.25 kilocalories

1 watt-hour = 3.4 BTU

1 TON of cooling = 12,000 BTU/hour

1 TON of refrigeration = 12000 Btu/hr
1 TON of refrigeration = 200 Btu/min
1 TON of refrigeration = 3.5 KJ/s
1 TON of refrigeration = 3.5 KW  



Total Heat Load:

The total heat load of a room/building is a function of:
1. Size of space to be cooled
2. Area of windows
3. Number of occupants
4. Equipment heat load
5. Lighting heat load

Total Heat Load
= Space Btu + Window Btu + Occupant Btu + Equipment Btu + Lighting Btu

 

   
Example:
Calculate the Total Heat Load and select an Air Conditioning Unit.

Room dimensions:
Length, L = 15 ft
Width, W = 10 ft
Height, H = 8 ft (2.5 m height from floor to ceiling)

Window dimensions:
L = 4 ft
W = 4 ft

Occupants:
2 persons

Equipment wattage:
TV = 100 watts
Radio = 50 watts
Laptop = 60 watts

Lighting Load:
60 watts light bulb


Air-conditioning Heat Load Estimation Formulas:


Total Heat Load
= Space Btu + Window Btu + Occupant Btu + Equipment Btu + Lighting Btu

Space Btu = Room Length (ft) x Room Width (ft) x 32

Window Btu = Total Window Area (sq. ft) x 80

Occupant Btu = Number of Occupants x 600

Equipment Btu = Total Equipment Wattage x 3.4

Lighting Btu = Total Lighting Wattage x 4.3


Total Heat Load Calculation:


Space Btu:
Space Btu = Room Length (ft) x Room Width (ft) x 32
Space Btu = L x W x 32
Space Btu = 15 x 10 x 32
Space Btu = 4800 Btu

Window Btu:
Window Btu = Total Window Area (sq. ft) x 80
Window Btu = Window Length (ft) x Window Width (ft) x 80
Window Btu = L x W x 80
Window Btu = 4 x 4 x 80
Window Btu = 1280 Btu

Occupant Btu:
Occupant Btu = Number of Occupants x 600
Occupant Btu = 2 persons x 600
Occupant Btu = 2 x 600
Occupant Btu = 1200 Btu

Equipment Btu:
Equipment Btu = Total Equipment Wattage x 3.4
Equipment Btu = (TV watts + Radio watts + Laptop watts) x 3.4
Equipment Btu = (100 watts + 50 watts + 60 watts) x 3.4
Equipment Btu = (100 + 50 + 60)  x 3.4
Equipment Btu = 714 Btu

Lighting Btu:
Lighting Btu = Total Lighting Wattage x 4.3
Lighting Btu = 60 watts x 4.3
Lighting Btu = 60 x 4.3
Lighting Btu = 258 Btu


Total Heat Load
= Space Btu + Window Btu + Occupant Btu + Equipment Btu + Lighting Btu
= 4800 + 1280 + 1200 + 714 + 258
= 8252 Btu

Select 8000 Btu to 10,000 Btu Air Conditioning Unit


Commercial Air Conditioner Unit Selection & Prices (July 2013):

5000 Btu Room Air Conditioner

150 sq. ft. bedroom (15 ft x 10 ft) or 15 sq. meter (5 m x 3 m)
Price: $100


8000 Btu Room Air Conditioner

300 sq. ft. master bedroom (20 ft x 15 ft) or 35 sq. meter (7 m x 5 m)
Price: $200


10,000 Btu Room Air Conditioner

450 sq. ft. living room (30 ft x 15 ft) or 50 sq. meter (10 m x 5 m)
Price: $400


See also:
1. Basics of Refrigeration and Air Conditioning
*.
*.
*.
*.
*.
*.



#RX#

Sunday, July 14, 2013

Why motors have large starting current

Reasons why motors have big starting current or inrush current:

- running motors produce back emf (electromotive force) in their coils

- back emf is caused by magnetic field which resists current (flow of electrons) through the armature winding

- back emf functions like a resistor which prevents current flow

- no back emf exists when motor is not running

- no back emf when motor is at rest

- at start up, resistance is zero (which is a short circuit condition), therefore current is large because no resistance to flow of current

- when a motor is running, the armature windings produce a resisting voltage (pressure) which opposes current flow as long as it is running

- a motor at rest acts like a transformer having secondary winding short circuited because the rotor windings in a squirrel cage induction motor is short circuited (closed circuit)

- starting currents (in-rush currents) for induction motors generally are 8 to 10 times the rated full load current

- a motor at rest has large inertia, therefore larger current is required to start it (this is similar to pushing a cart from stationary position, it's harder to push at the beginning, you need to exert a larger force and power, but as soon as the wheels start rolling, it is easier to push the car once it is moving)

Wednesday, June 12, 2013

What is air locking in pumps


Air Locking
  
- An air lock is trapped air or dissolved gases inside the pump impeller.
- This air or gas is compressed and becomes high pressure as the pump runs.


Causes of Air Lock:


- Leaks in the suction side
- Switch failure
- Entrained air mixed (dissolved) in the liquid


Dangers of air lock:


- overheating
- pump inability to start
- reduced flow of liquid
- pump unable to move fluid


How to prevent air lock in pumps:


- air relief valves
- repair leaks
- replace worn gaskets and seals
- operate within allowable limits

Sunday, March 10, 2013

How does an airplane, boat and ship propeller work?


Spinning of a Twisted Airfoil-Shaped Blade

Blade sections near the center have Lower Speed

Blade sections near the Tip have Higher Speed

Movement of Blade Draws Fluid (Air, Water, Liquid, Gas)

Speed is Inversely Proportional to Pressure (Bernoulli's principle)

Fluid near blade center have Lower Speed but Higher Pressure

Fluid near blade tip have Higher Speed but Lower Pressure
  

Drawing of Airfoil (Aerofoil) shape of Propeller Blade. 

  

Fluid flows from Higher Pressure to Lower Pressure

Every action has an equal and opposite reaction (Newton’s Third Law of Motion)

Propeller exerts force to the Water --> Water pushes the Ship, Boat forward

Propeller exerts force to the Air ------> Air pushes the Airplane, Aircraft forward

Pressure Differential creates Forward Force called Thrust --> Ship, Boat, Airplane

Pressure Differential produces Upward Force called Lift ----> Airplane, Aircraft


BLOG POSTS:
http://mechanical-marine-systems-engineering.blogspot.ca/

ALPHABETICAL LISTING OF ALL MY BLOGS:
http://miscellaneous-topics.blogspot.ca/2012/12/alphabetical-listing-of-all-my-blogs.html